3.      ELECTRICAL SUPPLY

3.1.Input Voltage:- The Atomiser needs a supply of 10 - 25 VoltsDC, Absolute Maximum 30 VDC.

The speed of the Spray Head is proportional to the voltage applied; maximum speed is at 25 V. There is a speed limiter incorporated in the electronics of the Atomiser, set at 32,500 rpm.

Input voltages higher than 30 VDC will destroy the electronics.

 3.2. Input Current:- Current consumption is proportional to speed, and the liquid flow rate through the unit. There is a current limiter incorporated in the electronics of the Atomiser, set at 2 Amps.

A special Power Supply for the Atomiser, allowing operation from the 230/115 VAC mains supply, is available from Newland Design - this unit also has a speed control. A 24 V battery supply is also suitable.

The Atomiser's body is electrically isolated but can be connected to earth if required.

3.3. Connector:->The Power Lead to the Atomiser is normally fitted with a ¼" jack plug connector, which fits in the socket on the Newland Design Power Supply unit. At option 4 mm plugs, or any other connector specified by the customer at time of ordering can be fitted.

The motor in the Atomiser is a BRUSHLESS DC motor which will NOT operate on a reversed-polarity supply. Be sure to connect correctly! (Brown or Red = +ve, Blue or Black = 0V). Prolonged connection to reverse polarity will destroy the electronics in the Atomiser, and may damage the supply.